Independent Peptide Testing · The Netherlands Know what’s really in the vial.

Your report 3–5 business days after your vial arrives. With Rush, within 24 hours.

Test a sample

PURITY FROM $129

Test together

SHARE THE COSTS

Join our Telegram community

UV · HPLC-DAD · HGH EXAMPLE
020040051015202530minmAU
020040051015202530minmAU

PURITY

99.67 %

MAIN PEAK

22.89 min

IMPURITIES

0.33 %

REPORTING LIMIT

0.10 %

A real HGH run from our HPLC. Time runs left to right, UV signal goes up. One clean peak means one dominant compound.

PURITY

HPLC-DAD

IDENTITY

LC–MS, 6130 MSD

REPORTING LIMIT

0.10 % (Ph. Eur.)

EVERY CERTIFICATE

Verifiable online

RESULTS IN 3–5 BUSINESS DAYSRUSH: WITHIN 24 HOURS OF DELIVERYIDENTITY TESTING ALWAYS BY LC–MSGROUP TESTING PLATFORM: TEST TOGETHER, PAY YOUR SHARE
COMMUNITY

Questions about testing? Ask the community.

Join the Nexora community on Telegram: questions about testing, group tests and reading a COA. We never post customer results or certificates there.

Join on Telegram

You send a request to join; a short check keeps spam out.

SCAN TO OPEN IN TELEGRAM

From vial to number

Five steps, in the same order for every sample.

Sample vials sorted in trays as they arriveNXL-2026-······

STEP 01

Logged on arrival

Each vial gets its own code, a photo and a seal check the moment it reaches the lab.

A pipette and a sample vial on the balance in our lab

STEP 02

Weighed and dissolved

Prepared by weight, so every number starts from a known amount.

UV · 3 RUNSEXAMPLE
BLANKSAMPLEBLANK
BLANKSAMPLEBLANK

STEP 03

Measured between blanks

Blank runs before and after the samples. A peak in a blank would mean carry-over, so we would see it.

MS · ESI+ · HGH · 10+ TO 16+EXAMPLE
1200160020002400m/z
1200160020002400m/z

EXPECTED MASS

22,124.8 Da

MUST BE WITHIN

± 3 Da

STEP 04

Confirmed by mass

The mass spectrometer sees the same molecule at several charges. Together they give its mass, which must match the expected mass within a fixed tolerance.

Peaks integratedFIXED RULES
Blanks comparedBEFORE · AFTER
Limits checked≥ 0.10 %
Reviewed by an analystRELEASED

STEP 05

Calculated, then reviewed

Fixed, versioned rules propose the result. An analyst checks it and releases it.

Zoom in. Small peaks count.

At full scale the main peak dominates. Twenty times closer, the rest of the vial shows up. Every peak from 0.10 % is on your report, with its retention time.

UV · 20.4–27.6 min ×20
01020212223242526minmAU
01020212223242526minmAU

MAIN PEAK

22.89 min

SIDE PEAKS

7

ON REPORT

1

One side peak passes the reporting limit: 24.06 min, 0.19 %. It goes on the report. The other six still count towards purity.

What a report tells you. And what it doesn’t.

Certificate of Analysis

NXL-2026-······

EXAMPLE
CompoundHGH 191AA
TestHPLC purity
PurityUV AREA %99.67 %
Largest impurityAT 24.06 min0.19 %
Reporting limit0.10 %
Quantification limit0.026 %
Scan the QR code, or enter the number and code on our site, to check the report is genuine.

IT TELLS YOU

How much of the UV signal comes from the main compound.
Whether its mass and retention time match our reference standard.
How many mg are in the vial, if you ordered Identity & Content.

IT DOESN’T TELL YOU

What share of the powder is peptide. 99% purity is not 99% of the weight.
Anything about vials we did not receive. A result applies to your sample only.
How to use it. We report measurements, never advice on use or dosing.

VERIFY

Got a certificate? Check it.

Enter the number and code from the certificate, or scan its QR code.